21 Beam Sections for One Steel Frame: H750 Down to H250
English Version
Title: 21 Beam Sections, One Frame: H750×320×16×20 Down to H250×150×6×8
Overview
A steel frame is not one beam repeated. It is a family of sections: deep girders over long spans, mid-size beams at secondary gridlines, light beams under slabs. Get the family right and the frame is economical; over-specify one section everywhere and you pay for steel you do not need.
This project's schedule lists 21 beam types — 13 frame beams (GL) and 8 composite/secondary beams (GCL) — all in Q355B, running from H750×320×16×20 down to H250×150×6×8.

Frame Beams — GL Series (from Drawing)
| Mark |
Name |
Section (H×B×tw×tf) |
Grade |
kg/m* |
| GL1 |
Frame beam |
H700×320×12×20 |
Q355B |
162.7 |
| GL2 |
Frame beam |
H400×200×8×12 |
Q355B |
61.3 |
| GL3 |
Frame beam |
H500×220×10×14 |
Q355B |
85.4 |
| GL4 |
Frame beam |
H600×250×10×14 |
Q355B |
99.9 |
| GL5 |
Frame beam |
H500×200×8×12 |
Q355B |
67.6 |
| GL6 |
Frame beam |
H700×280×12×16 |
Q355B |
133.3 |
| GL7 |
Frame beam |
H600×220×10×12 |
Q355B |
86.7 |
| GL8 |
Frame beam |
H750×320×16×20 |
Q355B |
189.7 |
| GL9 |
Frame beam |
H300×180×6×10 |
Q355B |
41.4 |
| GL10 |
Frame beam |
H700×250×12×14 |
Q355B |
118.3 |
| GL11 |
Frame beam |
H650×220×12×14 |
Q355B |
106.9 |
| GL12 |
Frame beam |
H700×270×12×16 |
Q355B |
130.7 |
| GL13 |
Frame beam |
H650×250×12×14 |
Q355B |
113.5 |
*kg/m calculated from the section dimensions at 7,850 kg/m³; the drawing gives sections only.

Composite and Secondary Beams — GCL Series (from Drawing)
| Mark |
Name |
Section |
Grade |
kg/m* |
| GCL1 |
Steel-concrete composite beam |
H500×200×6×8 |
Q355B |
47.9 |
| GCL2 |
Steel-concrete composite beam |
H450×180×6×8 |
Q355B |
43.0 |
| GCL3 |
Secondary beam |
H350×200×6×8 |
Q355B |
40.9 |
| GCL4 |
Steel-concrete composite beam |
H600×220×6×10 |
Q355B |
61.9 |
| GCL5 |
Steel-concrete composite beam |
H700×200×8×14 |
Q355B |
86.2 |
| GCL6 |
Secondary beam |
H250×150×6×8 |
Q355B |
29.9 |
| GCL7 |
Steel-concrete composite beam |
H700×280×8×14 |
Q355B |
103.7 |
| GCL8 |
Steel-concrete composite beam |
H500×200×8×12 |
Q355B |
67.6 |
Layout (from Drawing)
| Item |
Value |
| Plans |
Beam layout plans at two levels |
| Grid |
Axes ①–⑱ and Ⓐ–Ⓔ |
| Beam callouts |
GL / GCL marks at each bay and gridline |
What the Sections Tell You
- Depth tracks span. H750 for the long span, H600–H700 for the main frame lines, H300–H400 where spans are short or loads light.
- Flange thickness tracks moment. GL8 has 20 mm flanges at 320 wide; GL9 has 10 mm at 180 — four times the bending capacity, not four times the weight.
- Composite beams are thinner in the web. GCL sections run 6–8 mm webs against 10–16 mm on the GL beams; the concrete slab takes the compression, so the steel does less.
- One grade throughout. All 21 sections are Q355B — one steel to buy, one welding procedure, one set of consumables.
Advantages
- Steel where it is needed — 21 sections instead of 3 means the deep beams carry the span and the light beams carry only the slab.
- One grade — Q355B across the frame simplifies procurement, welding procedure, and inspection.
- Composite option — the GCL series lets the slab work with the steel, cutting beam weight under floors.
- Standard shapes — H-sections are familiar to every fabricator; detailing and connections follow normal practice.
- Clear take-off — a marked schedule means the estimator, the shop, and the site all read the same list.
Disadvantages / Limitations
- Many types to track — 21 marks means 21 nesting lists, 21 labels, and more chance of a beam going to the wrong bay.
- Heavy sections are hard to handle — H750×320×16×20 at ~190 kg/m is a crane lift, not a two-man carry.
- Composite beams need shear connection — the GCL series only works if the studs and slab are built as designed.
- Welded sections need checking — deep webs at 12–16 mm need stiffeners and weld inspection; rolled availability varies by size.
- Coordination load — beams, slab, and openings all compete for the same space; late changes hit several marks at once.
Typical Use Cases
- Industrial and warehouse frames — main girders on the long spans, secondary beams between.
- Multi-storey steel frames with concrete slabs — GCL composite beams under the floor.
- Mezzanine and platform framing — mixed GL/GCL layout at one level.
- Long-span roof structures — H700–H750 girders where deflection governs.
- Frames with mixed loads — heavy equipment on part of the floor, light storage elsewhere.

Fabrication and Erection Notes
- Check each mark against the plan before fabrication; GL and GCL sections are not interchangeable.
- For welded sections, set camber on the deep girders (GL1, GL6, GL8, GL10, GL12) before welding.
- Stiffeners at load points and at the connections; follow the connection details, not the schedule alone.
- Composite beams: place shear studs before the slab; confirm stud layout with the deck drawing.
- Label every member with its mark at the shop and keep the label visible until it is erected.
- Sequence: main frame beams first, secondary beams second, slab last.
Bottom Line
21 sections, one grade, one frame. The schedule does the work a good design should: H750 where the span is long, H300 where it is short, 6 mm webs where the slab helps, 20 mm flanges where the moment is high. Buy one steel, cut it to the list, and label every piece — the frame goes together in the order the drawing says.
**WhatsApp**: +86‑13889862778, +86‑18242444407
**Email**: eddie@zdsteels.com, wells@zdsteels.com