24 H-Section Frame Beams, H300–H1320: M20/M24 Rigid Column Connections, 4–28 Bolts per Joint, 8–12t Shear Plates

2026-11-25 22:28:47

24 H-Section Frame Beams, H300–H1320: M20/M24 Rigid Column Connections, 4–28 Bolts per Joint, 8–12t Shear Plates

English Version

Title: Steel H-Section Frame Beams — 24 Sections H300×180 to H1320×330, Rigid Beam-Column Joints, 4–28 M20/M24 Bolts, Double Shear Plates 8/10/12 mm, Standard Connection Table 1

Drawing note: sections, bolt sets and shear-plate thickness are read from connection Table 1 (frame beam to frame column, rigid joint). Beam spans, lengths, weights, steel grade and loads are not listed in this batch; they remain on the original frame drawings.


Overview

This is the rigid frame beam set for a steel frame. Twenty-four welded H-sections range from H300×180×6×10 to H1320×330×12×14. Each joint uses flange and web bolts plus double shear plates; the connection table pairs each beam size with its bolt count, bolt spacing and plate thickness. M20 bolts cover sections up to H750; the two deepest beams use M24.


blog-312-464


Connection Table 1 — Beam to Column, Rigid Joint

 

Beam section a (mm) b (mm) m×d n×s Bolts Shear plate
H700×320×12×20 45 50 1×70 7×70 16-M20 8t double shear
H700×330×14×20 45 50 1×70 7×70 16-M20 10t double shear
H750×320×16×20 45 50 1×70 8×70 18-M20 10t double shear
H700×290×12×16 45 50 1×70 7×70 16-M20 8t double shear
H700×250×12×14 45 50 1×70 7×70 16-M20 8t double shear
H700×270×12×16 45 50 1×70 7×70 16-M20 8t double shear
H650×220×12×14 45 65 1×70 6×70 14-M20 8t double shear
H650×250×12×14 45 65 1×70 6×70 14-M20 8t double shear
H700×260×12×16 45 50 1×70 7×70 16-M20 10t double shear
H600×250×10×14 45 70 1×70 5×70 12-M20 12t double shear
H600×220×10×14 45 70 1×70 5×70 12-M20 12t double shear
H600×250×10×12 45 70 1×70 5×70 12-M20 12t double shear
H600×220×10×12 45 57 1×70 6×66 12-M20 12t double shear
H600×180×10×10 45 70 1×70 5×70 12-M20 12t double shear
H550×220×10×12 45 80 1×70 4×70 10-M20 12t double shear
H550×200×10×12 45 80 1×70 4×70 10-M20 12t double shear
H500×200×8×12 45 55 1×70 4×70 10-M20 10t double shear
H400×200×8×12 45 50 1×70 3×70 8-M20 10t double shear
H350×200×8×12 45 50 1×70 2×70 6-M20 10t double shear
H350×180×6×10 45 50 1×70 2×70 6-M20 10t double shear
H300×180×6×10 45 60 1×70 1×70 4-M20 10t double shear
H600×250×10×12 45 70 1×70 5×70 12-M20 12t double shear
H1200×390×12×16 55 70 1×80 11×80 24-M24 10t double shear
H1320×330×12×14 55 70 1×80 13×80 28-M24 10t double shear

a, b = edge distances; m×d = flange bolt row; n×s = web bolt rows × spacing; plate thickness per original joint detail.


blog-389-198


Section Groups

 

Group Sections Joint detail
Deep transfer beams H1200×390×12×16; H1320×330×12×14 M24, 24 / 28 bolts, 80 mm pitch
Main H700 beams H700 series, H750×320×16×20 M20, 16–18 bolts, 70 mm pitch
Mid-height beams H650, H600, H550, H500 M20, 10–14 bolts
Secondary beams H400, H350, H300 M20, 4–8 bolts

How the Joint Works

  • Flange bolts carry moment. Top and bottom flange bolt rows (m×d) transfer tension and compression at the rigid joint.
  • Web bolts carry shear. n×s web rows transfer vertical shear to the column.
  • Shear plates back the web. Double shear plates of 8/10/12 mm thickness distribute the web force and stiffen the connection zone.
  • Section scales with demand. Deeper and wider beams carry more moment, so bolt count rises from 4-M20 on H300 to 28-M24 on H1320.
  • Rigid frame resists lateral load. Beam-column moment joints transfer frame bending to columns and foundations under wind and crane load.

Advantages

  1. Standardized joint table — each section has a fixed bolt count, spacing and plate thickness, speeding shop and site layout.
  2. Wide section range — H300 to H1320 covers secondary, main and transfer beams in one system.
  3. Bolted rigid connection — site assembly avoids field welding at the joint; inspection is by bolt torque.
  4. Double shear plates — web force is shared between two plates, reducing single-plate buckling risk.
  5. Clear sizing steps — bolt count follows beam depth and flange size, so selection matches the design moment.

blog-419-166


Disadvantages / Limits

  1. Joint fabrication accuracy — bolt holes in beam end, column stiffener and shear plate must align; misaligned holes slow erection.
  2. Rigid joint stiffness depends on plates — plate thickness and stiffener layout control panel-zone deformation; under-sized plates add drift.
  3. Deep beams add headroom — H1200/H1320 transfer beams need clear depth and heavier columns and foundations.
  4. Fire and corrosion protection — exposed beam ends and plates need coating continuity and access for maintenance.
  5. Data gaps on these drawings — steel grade, beam length, span, member weight, bolt grade and torque value are not listed; member capacity and detailing need the original frame design.

Typical Use Cases

  1. Portal and rigid-frame industrial workshops with main and secondary H-beams.
  2. Warehouse and logistics frame structures carrying roof and crane loads.
  3. Multi-storey steel buildings — frame beams between steel columns.
  4. Transfer beams over large openings, courts or equipment bays.
  5. Commercial and exhibition steel frames with regular column grids and rigid beam-column joints.

Fabrication and Erection Notes

  • Confirm steel grade, bolt grade and torque against the original design before fabrication.
  • Match each beam to its Table 1 row: section, a/b edge distances, flange row, web rows and bolt count.
  • Drill holes to the n×s and m×d pitch; keep 70 mm pitch (80 mm on the two M24 deep beams).
  • Fit 8/10/12 mm double shear plates at the web; check plate contact and stiffener alignment.
  • Tighten bolts to the specified sequence and torque; mark installed bolts for inspection.
  • Protect exposed ends and plates with the specified coating; reserve access for later inspection.

Bottom Line

A set of welded H-section frame beams: 24 sections from H300×180×6×10 to H1320×330×12×14, rigid beam-column joints with M20/M24 bolts from 4 to 28 per joint, flange row 1×70/1×80, web rows 1×70 to 13×80, and 8–12t double shear plates. The table pairs each section with its connection detail; grade, span, length and weight follow the original frame design.

**WhatsApp**: +86‑13889862778, +86‑18242444407
**Email**: eddie@zdsteels.com, wells@zdsteels.com

Next Article: 7 C250×75×20 Purlin Types, 13.0 m Wall, 6 Bays, 12.5 m High: Steel Wall Cladding Framing with Φ12 Tie Rods and 2C Welded Members

YOU MAY LIKE