24 H-Section Frame Beams, H300–H1320: M20/M24 Rigid Column Connections, 4–28 Bolts per Joint, 8–12t Shear Plates
English Version
Title: Steel H-Section Frame Beams — 24 Sections H300×180 to H1320×330, Rigid Beam-Column Joints, 4–28 M20/M24 Bolts, Double Shear Plates 8/10/12 mm, Standard Connection Table 1
Drawing note: sections, bolt sets and shear-plate thickness are read from connection Table 1 (frame beam to frame column, rigid joint). Beam spans, lengths, weights, steel grade and loads are not listed in this batch; they remain on the original frame drawings.
Overview
This is the rigid frame beam set for a steel frame. Twenty-four welded H-sections range from H300×180×6×10 to H1320×330×12×14. Each joint uses flange and web bolts plus double shear plates; the connection table pairs each beam size with its bolt count, bolt spacing and plate thickness. M20 bolts cover sections up to H750; the two deepest beams use M24.

Connection Table 1 — Beam to Column, Rigid Joint
| Beam section |
a (mm) |
b (mm) |
m×d |
n×s |
Bolts |
Shear plate |
| H700×320×12×20 |
45 |
50 |
1×70 |
7×70 |
16-M20 |
8t double shear |
| H700×330×14×20 |
45 |
50 |
1×70 |
7×70 |
16-M20 |
10t double shear |
| H750×320×16×20 |
45 |
50 |
1×70 |
8×70 |
18-M20 |
10t double shear |
| H700×290×12×16 |
45 |
50 |
1×70 |
7×70 |
16-M20 |
8t double shear |
| H700×250×12×14 |
45 |
50 |
1×70 |
7×70 |
16-M20 |
8t double shear |
| H700×270×12×16 |
45 |
50 |
1×70 |
7×70 |
16-M20 |
8t double shear |
| H650×220×12×14 |
45 |
65 |
1×70 |
6×70 |
14-M20 |
8t double shear |
| H650×250×12×14 |
45 |
65 |
1×70 |
6×70 |
14-M20 |
8t double shear |
| H700×260×12×16 |
45 |
50 |
1×70 |
7×70 |
16-M20 |
10t double shear |
| H600×250×10×14 |
45 |
70 |
1×70 |
5×70 |
12-M20 |
12t double shear |
| H600×220×10×14 |
45 |
70 |
1×70 |
5×70 |
12-M20 |
12t double shear |
| H600×250×10×12 |
45 |
70 |
1×70 |
5×70 |
12-M20 |
12t double shear |
| H600×220×10×12 |
45 |
57 |
1×70 |
6×66 |
12-M20 |
12t double shear |
| H600×180×10×10 |
45 |
70 |
1×70 |
5×70 |
12-M20 |
12t double shear |
| H550×220×10×12 |
45 |
80 |
1×70 |
4×70 |
10-M20 |
12t double shear |
| H550×200×10×12 |
45 |
80 |
1×70 |
4×70 |
10-M20 |
12t double shear |
| H500×200×8×12 |
45 |
55 |
1×70 |
4×70 |
10-M20 |
10t double shear |
| H400×200×8×12 |
45 |
50 |
1×70 |
3×70 |
8-M20 |
10t double shear |
| H350×200×8×12 |
45 |
50 |
1×70 |
2×70 |
6-M20 |
10t double shear |
| H350×180×6×10 |
45 |
50 |
1×70 |
2×70 |
6-M20 |
10t double shear |
| H300×180×6×10 |
45 |
60 |
1×70 |
1×70 |
4-M20 |
10t double shear |
| H600×250×10×12 |
45 |
70 |
1×70 |
5×70 |
12-M20 |
12t double shear |
| H1200×390×12×16 |
55 |
70 |
1×80 |
11×80 |
24-M24 |
10t double shear |
| H1320×330×12×14 |
55 |
70 |
1×80 |
13×80 |
28-M24 |
10t double shear |
a, b = edge distances; m×d = flange bolt row; n×s = web bolt rows × spacing; plate thickness per original joint detail.

Section Groups
| Group |
Sections |
Joint detail |
| Deep transfer beams |
H1200×390×12×16; H1320×330×12×14 |
M24, 24 / 28 bolts, 80 mm pitch |
| Main H700 beams |
H700 series, H750×320×16×20 |
M20, 16–18 bolts, 70 mm pitch |
| Mid-height beams |
H650, H600, H550, H500 |
M20, 10–14 bolts |
| Secondary beams |
H400, H350, H300 |
M20, 4–8 bolts |
How the Joint Works
- Flange bolts carry moment. Top and bottom flange bolt rows (m×d) transfer tension and compression at the rigid joint.
- Web bolts carry shear. n×s web rows transfer vertical shear to the column.
- Shear plates back the web. Double shear plates of 8/10/12 mm thickness distribute the web force and stiffen the connection zone.
- Section scales with demand. Deeper and wider beams carry more moment, so bolt count rises from 4-M20 on H300 to 28-M24 on H1320.
- Rigid frame resists lateral load. Beam-column moment joints transfer frame bending to columns and foundations under wind and crane load.
Advantages
- Standardized joint table — each section has a fixed bolt count, spacing and plate thickness, speeding shop and site layout.
- Wide section range — H300 to H1320 covers secondary, main and transfer beams in one system.
- Bolted rigid connection — site assembly avoids field welding at the joint; inspection is by bolt torque.
- Double shear plates — web force is shared between two plates, reducing single-plate buckling risk.
- Clear sizing steps — bolt count follows beam depth and flange size, so selection matches the design moment.

Disadvantages / Limits
- Joint fabrication accuracy — bolt holes in beam end, column stiffener and shear plate must align; misaligned holes slow erection.
- Rigid joint stiffness depends on plates — plate thickness and stiffener layout control panel-zone deformation; under-sized plates add drift.
- Deep beams add headroom — H1200/H1320 transfer beams need clear depth and heavier columns and foundations.
- Fire and corrosion protection — exposed beam ends and plates need coating continuity and access for maintenance.
- Data gaps on these drawings — steel grade, beam length, span, member weight, bolt grade and torque value are not listed; member capacity and detailing need the original frame design.
Typical Use Cases
- Portal and rigid-frame industrial workshops with main and secondary H-beams.
- Warehouse and logistics frame structures carrying roof and crane loads.
- Multi-storey steel buildings — frame beams between steel columns.
- Transfer beams over large openings, courts or equipment bays.
- Commercial and exhibition steel frames with regular column grids and rigid beam-column joints.
Fabrication and Erection Notes
- Confirm steel grade, bolt grade and torque against the original design before fabrication.
- Match each beam to its Table 1 row: section, a/b edge distances, flange row, web rows and bolt count.
- Drill holes to the n×s and m×d pitch; keep 70 mm pitch (80 mm on the two M24 deep beams).
- Fit 8/10/12 mm double shear plates at the web; check plate contact and stiffener alignment.
- Tighten bolts to the specified sequence and torque; mark installed bolts for inspection.
- Protect exposed ends and plates with the specified coating; reserve access for later inspection.
Bottom Line
A set of welded H-section frame beams: 24 sections from H300×180×6×10 to H1320×330×12×14, rigid beam-column joints with M20/M24 bolts from 4 to 28 per joint, flange row 1×70/1×80, web rows 1×70 to 13×80, and 8–12t double shear plates. The table pairs each section with its connection detail; grade, span, length and weight follow the original frame design.
**WhatsApp**: +86‑13889862778, +86‑18242444407
**Email**: eddie@zdsteels.com, wells@zdsteels.com