Title: Steel–Concrete Composite Box Girder Bridge — 411.3 t Q355MD Steel Plate, 10.3 m Deck, Twin-Cell Box 7.3 m Bottom Width, 1,476 kg Shear Studs, 3,258 m² Inner Coating

Drawing note: the material table splits the superstructure into a composite girder and a cast-in-place concrete box girder. The steel subject below is taken from the composite-girder column (Q355MD plate); the standard cross-section is taken from the standard cross-section drawing. Concrete box-girder items (C50 812.45 m³, prestressing strand 24,448.4 kg) are concrete members and are listed separately, not as steelwork. Span length and bearing size are not given on these drawings.


blog-567-563


Overview

The composite superstructure uses a welded Q355MD steel box paired with a C50 compensated-shrinkage concrete deck. The standard section is a twin-cell box: overall deck width 10,300 mm, bottom width 7,300 mm, depth 1,600 mm, with 1,500 mm cantilevers on each side. Shear studs connect the steel top flange to the concrete slab; three coating zones are measured separately inside, outside and on contact surfaces.


Standard Cross-Section (1:75)

 

Item Value
Overall deck width 10,300 mm; carriageway 9,300 mm; edge 500 mm each
Bottom width 7,300 mm; 500 + 2,900 + 500 + 2,900 + 500
Cantilever 1,500 mm each side
Section depth 1,600 mm; cantilever tip 200 mm; root 450 mm
Top / bottom slab thickness 250 mm
Cell chamfer Left 800×200; right 250×250
Cross fall 5%
Centerline offset Box centerline 150 mm from road design line
Deck build-up 100 mm asphalt + waterproof layer + 80 mm cast-in-place C50

Steelwork and Composite Materials (Composite Girder Column)

表格

Item Grade / spec Quantity Unit
Main steel plate Q355MD 411,317.2 kg (≈411.32 t)
Secondary plate Q235 1,367.7 kg
Milled steel fiber — 151,815 kg
Shear studs ML15 Φ22×200 14,766 kg
Stainless pipe Φ70×6×40 4 pieces
Plain bolts, B-grade M24×80, 8.8 48 sets
Internal coating — 3,258.08 m²
External coating — 1,846.98 m²
Contact-surface coating — 593.4 m²
Deck concrete C50 compensated-shrinkage 303.63 m³
Rebar total HRB400 107,176.5 kg (≈107.18 t)

Rebar breakdown: Φ28 41,731.2 kg; Φ22 13,663.3 kg; Φ16 39,311 kg; Φ12 12,471 kg.


blog-396-796


How It Works

  • Steel box carries the span. The Q355MD plate box resists bending and shear between bearings.
  • Concrete slab works compositely. Φ22×200 shear studs anchor the C50 slab to the top flange; the slab resists compression, the steel resists tension.
  • Twin cells distribute load. Two cells with 250 mm top and bottom slabs share wheel loads and give torsional stiffness.
  • Coating zones protect the steel. Inner, outer and contact surfaces are measured separately; hidden contact areas are coated before closure.
  • 5% cross fall drains the deck. The 80 mm C50 base, waterproof layer and 100 mm asphalt keep water off the steel.

blog-790-516


Advantages

  1. Composite efficiency — steel and concrete share the section, cutting steel weight versus a bare steel box.
  2. Shallow 1.6 m depth — suits limited headroom over roads, railways or existing structures.
  3. Wide 10.3 m deck — fits a two-way carriageway with edge strips in one section.
  4. Durable finish — three coating zones plus asphalt and waterproofing reduce long-term maintenance.
  5. Quantities are takeoff-ready — plate, studs, fiber, bolts, coatings and rebar are itemized per member.

Disadvantages / Limits

  1. Composite action depends on studs — stud welding, pull-out and layout must match the design; missing studs reduce the composite section.
  2. Deck concrete shrinkage — the slab needs curing and control joints; cracking exposes the top flange to moisture.
  3. Internal inspection — closed cells require hatches, drainage and ventilation before welding the last plate.
  4. Coating at joints and contact surfaces — bolted and contact areas must be touched up after erection; hidden zones are easy to miss.
  5. Data gaps on these drawings — span, beam segments, lift weight, bearing type and rebar spacing are not listed here; capacity and detail need the original layout and fabrication drawings.

Typical Use Cases

  1. Urban road overpasses crossing streets, railways or canals with limited clearance.
  2. Expressway ramps and interchange bridges where a wide, shallow section is needed.
  3. Pedestrian and cycle bridges carrying a concrete deck over a landscape or waterway.
  4. Movable-area retrofit where prefabricated steel box segments speed erection over live traffic.
  5. Commercial and industrial skybridges between buildings or over yards.

Fabrication and Erection Notes

  • Verify Q355MD and Q235 mill certificates; steel fiber and studs are sourced per the composite design.
  • Set out from the box centerline; check 10,300 mm width, 7,300 mm bottom width and 1,600 mm depth.
  • Coat contact surfaces before assembly; keep 593.4 m² contact coating protected until bolts are tightened.
  • Weld Φ22×200 studs per layout; inspect studs before placing the C50 slab.
  • Deck sequence: C50 compensated-shrinkage concrete, curing, waterproof layer, 100 mm asphalt; maintain the 5% fall.
  • Apply internal and external coating after final weld NDT; reserve hatches for inspection and drainage.

Bottom Line

A Q355MD steel–concrete composite box girder: ≈411.32 t main plate, 10.3 m wide, twin-cell section 7.3 m wide and 1.6 m deep, 14,766 kg shear studs, 48 M24 bolts, 3,258.08 m² internal coating. The composite slab shares compression with the steel box; quantities and section dimensions come from the drawings, while span, bearings and segment weights remain on the original design

**WhatsApp**: +86‑13889862778, +86‑18242444407
**Email**: eddie@zdsteels.com, wells@zdsteels.com

Next Article: 131.2 t Q345qE Steel Pedestrian Overpass: 4.9 m Box Section, 8 Bearings, 216 m² Waterproof Deck