Steel Roof Purlin System: 5 Purlin Types in Rectangular Tube and Cold-Formed C, Q355B, φ12 Tie Rods with φ12+φ32×2.5 Spreaders, Double-Layer Layout
English Version
Title: Q355B Steel Roof Purlin System — B200×100, B250×150, B300×200 Rectangular Tubes, C250 and Double 2C280 Cold-Formed Sections, φ12 Tie Rods and φ12+φ32×2.5 Spreaders on Two Layers
Drawing note: member marks, sections, grades and remarks are read from the component schedule and the two roof plans. Purlin length, quantity, total weight, purlin spacing, roof sheet type and thickness, roof pitch, wind/snow load and connection bolts are not listed in this batch; they follow the original material schedule and detail drawings.

Overview
This roof system combines five purlin types with tie rods and spreaders to support the roof sheet. Rectangular tube purlins WL-1, WL-3 and WL-1a carry heavier spans; cold-formed C purlins WL-2 and the double back-to-back WL-2a cover lighter and edge bays. Round tie rods T and XT, plus spreader CG (φ12 core bar inside a φ32×2.5 sleeve), are arranged in two layers to keep the purlins straight and prevent lateral twisting. The plans cover frame axes 19–26 and longitudinal axes A–P.
Readable Drawing Data
Purlins (all Q355B)
| Mark |
Name |
Section |
Type |
Reference weight |
| WL-1 |
Purlin |
B200×100×4.00 |
Rectangular tube |
≈18.34 kg/m |
| WL-2 |
Purlin |
C250×75×20×2.5 |
Cold-formed C |
— |
| WL-3 |
Purlin |
B300×200×5.00 |
Rectangular tube |
≈38.47 kg/m |
| WL-1a |
Purlin |
B250×150×5.00 |
Rectangular tube |
≈30.62 kg/m |
| WL-2a |
Purlin |
2C280×80×20×2.5 |
Back-to-back double cold-formed C |
— |
Tie rods and spreaders (all Q235B, double-layer layout)
| Mark |
Name |
Section |
Remark |
| T |
Straight tie rod |
φ12 round bar |
Round bar, double layer |
| XT |
Diagonal tie rod |
φ12 round bar |
Round bar, double layer |
| CG |
Spreader (撑杆) |
φ12 + φ32×2.5 |
Round bar cased in steel tube, double layer |
Weight figures for rectangular tubes are calculated at 7,850 kg/m³ and are derived reference values; takeoff weight must use the original schedule.

How the Roof System Works
- Purlins span between roof trusses or rafters and carry roof sheet, insulation and service loads down to the main steel frame.
- Rectangular tube purlins resist bending and torsion with a closed section; they are chosen where span or load is heavier.
- Cold-formed C purlins are light and easy to fix; the double back-to-back 2C section combines two C members for extra depth at selected bays.
- Straight tie rods T connect purlins along the span, limiting purlin deflection and lateral movement between supports.
- Diagonal tie rods XT brace the purlin line in the longitudinal direction; spreaders CG hold the two layers of tie rods at fixed spacing.
Advantages
- Section selection matches the load — tube, single C and double C purlins are matched to bay span and load instead of using one heavy section everywhere.
- Q355B purlins give strength with moderate weight — higher grade than the tie rods, so the purlin span can cover longer bays.
- Closed tube section is stiff in torsion — rectangular tube purlins resist twisting under wind suction and uneven snow.
- Double-layer tie rods stabilize the purlin line — straight and diagonal φ12 rods plus spreaders keep purlins aligned and reduce weak-axis buckling.
- Standard cold-formed sections are fast to erect — C and double-C purlins drill and bolt on site without heavy welding at the purlin line.
Disadvantages / Limits
- Five purlin types mean more end plates, holes and inventory — fabrication and site sorting must keep WL-1/2/3/1a/2a separate.
- C-section purlins have a weak axis — single C members need tie rods and edge restraint; without them they twist under load.
- Tie rods are Q235B round bar — tension-only members; rod size and turnbuckle or end plate must follow the detail, and rods must be checked for looseness after erection.
- Spreader sleeve needs length control — the φ12 bar inside φ32×2.5 tube must stay centered; short sleeves or missed welds reduce spreader stiffness.
- Data gaps on these drawings — purlin length, count, total weight, purlin spacing, roof sheet, pitch, load values and bolt grade are not legible; capacity and material takeoff need the original design.
Typical Use Cases
- Industrial workshop and warehouse steel roofs with mixed bay spans where tube and C purlins are used together.
- Cold-formed roof over portal frames needing light purlins with rod bracing.
- Heavy-load bays covered by B300×200 and B250×150 rectangular tube purlins.
- Edge and ridge bays using single C250 or double 2C280 back-to-back purlins.
- Retrofit roof sections where purlin lines must tie into an existing frame with φ12 rod bracing.
Fabrication and Erection Notes
- Confirm purlin length, spacing, count and bolt specification from the original schedule before cutting sections.
- Keep the five purlin types tagged at the shop; match section mark WL-1, WL-2, WL-3, WL-1a, WL-2a to the roof plan locations.
- Drill tie-rod holes straight across the purlin web; fit T straight rods first, then XT diagonals and CG spreaders.
- Check that CG sleeves center the φ12 bar; weld or pin sleeve ends per detail.
- Erect purlins in line; tighten tie rods after purlin alignment, and re-check rod tension before roof sheet fixing.
- Inspect purlin ends, rod connections and sleeve welds, then apply coating as specified.

Bottom Line
The roof system uses five Q355B purlin sections — three rectangular tubes (B200×100×4, B250×150×5, B300×200×5), one single C250×75×20×2.5 and one back-to-back 2C280×80×20×2.5 — stabilized by Q235B φ12 straight and diagonal tie rods and φ12+φ32×2.5 spreaders in a double-layer layout, shown on plans for axes 19–26 and A–P. Sections and grades come from the schedule; lengths, quantities, connections and loads follow the original structural design.
**WhatsApp**: +86‑13889862778, +86‑18242444407
**Email**: eddie@zdsteels.com, wells@zdsteels.com