Title: 340.2 kg Single Round-Tube Column GZ-2 — Φ219×12 Pipe, 2.882 m Long, H(180–272)×180×6×8 Head Beam on a 3.15 m Cap

Data note: all member specs, lengths and weights are read from the GZ-2 bill of materials and the 1-1 section. Weights are the BOM figures; the pipe unit weight below is derived at 7,850 kg/m³. Weld allowance is listed separately at 1.5%.


blog-532-343


Overview

GZ-2 is one independent steel round-tube column. A Φ219×12 Q235B pipe forms the shaft; a welded tapered H beam branches left and right at the head; a base plate with radial stiffeners sits on a concrete cap and is fixed by four M20×60 high-strength bolts. Total weight of the member is 340.2 kg, one piece.


blog-530-341


Readable Drawing Data

 

Item Value
Column mark GZ-2
Quantity 1 pc
Total weight 340.2 kg (incl. 4.4 kg weld allowance, 1.5%)
Shaft member O-1, Φ219×12 round tube, L=2,882 mm
Shaft weight 176.6 kg
Head beam H(180–272)×180×6×8 welded tapered H, 2×2,000 mm sides
Base plate P-1, PL20×559, L=558 mm, 49.0 kg
Bolt set M20×60 high-strength bolt, 4 pcs, grade HS
Overall column height 2,900 mm; clear shaft 2,526 mm
Head beam total width 4,000 mm (2,000 + 2,000)
Base plate spread 280 + 280 mm about axis A2
Cap concrete 3,150 mm wide, 150 mm thick; top level 0.220
Top level 0.300
Roof finish 0.6 mm profiled steel sheet, 5% dual-direction fall
Section scale 1:50

Bill of Materials

表格

Part Spec Length (mm) Grade Qty Unit wt (kg) Total wt (kg)
O-1 Φ219×12 pipe 2,882 Q235B 1 176.6 176.6
I-1 I10 150 Q235B 1 1.7 1.7
P-1 PL20×559 558 Q235B 1 49.0 49.0
P-2 PL8×140 200 Q235B 8 1.8 14.1
P-21 PL10×479 874 Q235B 1 32.9 32.9
P-22 PL10×479 884 Q235B 1 33.3 33.3
P-23 PL6×315 272 Q235B 2 4.0 8.1
P-24 PL8×130 265 Q235B 2 2.2 4.3
P-29 PL6×180 180 Q235B 2 1.5 3.1
P-30 PL6×100 170 Q235B 2 0.8 1.6
P-47 PL8×331 266 Q235B 2 5.5 11.1
Welds 1.5% allowance — — — 4.4 4.4
Total — — — — — 340.2

Derived check: Φ219×12 tube weighs about 61.3 kg/m at 7,850 kg/m³; 2.882 m gives ≈176.6 kg, matching the BOM line.


Member Breakdown

 

Function Part Description
Shaft O-1 Round hollow section carries axial load and moment
Head beam H(180–272)×180×6×8 Tapered welded H, two cantilever sides, supports purlins/roof
Base plate P-1 PL20×559 Distributes shaft load to the cap
Stiffeners / cleats P-2, P-21, P-22, P-23, P-24, P-29, P-30, P-47 Node plates and radial ribs around shaft and head
Small section I-1 I10 Short connection cleat, 150 mm
Anchor 4×M20×60 HS Fixes base plate to concrete cap

How the Column Works

Shaft takes axial force and moment. The round tube carries vertical load; its closed section resists local buckling better than an open angle or channel.

Head beam branches to the roof. The tapered H beam spans left and right; depth grows toward the column where moment is highest.

Base plate spreads the reaction. PL20×559 transfers shaft force into the cap; stiffeners keep the plate from bending under the column.

Anchor bolts hold uplift and moment. Four M20×60 high-strength bolts resist tension and shear at the base; the cap must be designed for the same reaction.


blog-530-341


Advantages

Clean round shaft — a circular tube reads neatly in open-side sheds and canopies; no exposed angle toes.

Good axial and buckling behavior — closed CHS section handles compression with favorable radius of gyration.

Single-column layout — one post per support point leaves interior space free of knee bracing.

Integrated head beam — the welded H branch carries roof purlins directly, one column-to-roof node.

Standard sections — Φ219×12 tube, I10 cleat and plate sizes are common stock; fabrication is straightforward.


Disadvantages / Limits

Closed tube hides interior corrosion — sealed ends can trap moisture; ends need sealing, venting and internal coating where specified.

Base design carries the moment — plate, bolts and cap must resist lateral load; a weak foundation limits the column.

Node fit-up matters — tube-to-H-head and tube-to-plate welds need angle cuts and jigs to keep the shaft plumb.

Lateral stability comes from the roof — an independent post cannot stand alone in wind; roof bracing and purlin ties are required.

Tapered H fabrication — depth changes 180–272 mm along the cantilever; web cutting and flange rolling must follow the detail.


Typical Use Cases

Single-story industrial sheds and workshops where interior bracing would block layout.

Entrance canopies and gate posts needing a neat round exposed column.

Open-side warehouses and loading bays with unobstructed floor space.

Equipment platforms and pipe-rack support posts.

Parking sheds and small-span awning frames on independent bases.


Fabrication and Erection Notes

Material: Q235B; check mill certificate against the BOM.

Cut the Φ219×12 shaft to 2,882 mm; verify straightness and end square.

Weld the PL20×559 base plate and radial stiffeners first; keep the shaft vertical on the jig.

Assemble the tapered H head beam; match the 180–272 mm depth profile and the 180 mm flange width.

Use the four M20×60 high-strength bolts at the base; do not substitute ordinary bolts without design approval.

Seal tube ends, apply the specified corrosion protection, and connect roof bracing before releasing the temporary support.


Bottom Line

GZ-2 is a 340.2 kg independent round-tube column: Φ219×12 Q235B shaft, tapered welded H head beam, PL20×559 base plate, four M20×60 anchor bolts. It suits open-side sheds and canopies where a single clean post carries the roof branch. Capacity and foundation reaction still depend on the original structural design; this article covers the member data on the drawing.