C300 Steel Roof Purlins: The 300 mm Backbone for Long-Span Roofs

2026-10-18 23:19:20

C300 Steel Roof Purlins: The 300 mm Backbone for Long-Span Roofs

C-section steel purlins are the horizontal members supporting roof cladding between rafters. Below is data from an actual LC300 purlin system drawing.


Basic Specs

 

Item Value
Purlin type C-section (LC300×80×20)
Heights 300 mm
Flange width 80 mm
Lip size 20 mm
Wall thickness 2.5 mm (LT1) / 3.0 mm (LT2)
Material Q355B
Tie rods Φ12 round bar, Q235B
Knee braces L63×5 angle, Q235B
Spacer tubes D32×2.5, Q235B

blog-445-518


Purlin Schedule

 

Name Size Thickness Material Use
LT1 LC300×80×20 2.5 mm Q355B Standard purlin
LT2 LC300×80×20 3.0 mm Q355B Heavy load purlin
WLT1–WLT6 Φ12 — Q235B Sag rods
WXL1–WXL3 Φ12 — Q235B Diagonal tie
WYC L63×5 — Q235B Knee brace
WCG1–WCG4 D32×2.5 2.5 mm Q235B Spacer tube

Why C300 Purlins

  1. 300 mm depth — deep section spans longer distances, fewer purlins needed
  2. Q355B strength — higher yield than Q235, allows longer spans between rafters
  3. C-section efficiency — lip stiffeners prevent flange buckling under load
  4. Galvanized option — cold-formed galvanized for corrosion resistance
  5. Complete system — purlins + tie rods + knee braces + spacers, all in one package

Advantages

  1. Longer spans — 300 mm deep purlins span 6–9 m between rafters
  2. Lightweight — cold-formed steel is light yet strong per kg
  3. Fast installation — bolted to cleats, no welding on site
  4. Versatile — fits metal panels, sandwich panels, FRP sheets
  5. Cost effective — standard cold-formed sections, low material cost

 

blog-820-550

Disadvantages / Limitations

  1. Needs sag rods — 300 mm deep purlins still need Φ12 tie rods at midspan
  2. Thin wall dents — 2.5–3.0 mm wall damages easily during handling
  3. Corrosion at cuts — cut edges lose galvanized coating, need touch-up
  4. Not for heavy loads — C300 only for roof, not floor or crane loads
  5. Fire rating — thin steel needs fire protection for rated buildings

Typical Applications

  1. Large-span factory roofs — 6–9 m rafter spacing, C300 purlins
  2. Warehouse & logistics centers — long clear spans, light roof
  3. Steel structure workshops — standard purlin system
  4. Aircraft hangars — huge roof area, uniform purlin grid
  5. Exhibition halls — column-free space, long-span purlins

Installation Notes

  • Purlins bolted to steel cleats on rafter top flange
  • Φ12 sag rods installed at midspan every other purlin
  • L63×5 knee braces connect purlin to rafter for lateral stability
  • D32×2.5 spacer tubes at support points for stiffening

blog-5472-3078​​​​​​​

**WhatsApp**: +86‑13889862778, +86‑18242444407
**Email**: eddie@zdsteels.com, wells@zdsteels.com

Previous article: 6.5-Meter Cantilever Steel Canopy: No Columns, Just Steel and Shade