Simple Warehouse vs. Prefabricated Steel Warehouse: Cost and Lead Time

2026-10-27 13:00:01

C250 Wall Girts: The Complete System Behind Every Factory Wall

Steel wall systems are more than girts — they include columns, braces, sag rods and canopy beams all working together. Below is data from an actual 48.5 m long factory wall system.


 

blog-1195-490


Basic Specs

 

Item Value
Wall length 48.5 m (6 bays × 8 m)
Wall height ~13.2 m
Girt spacing 1,200 mm
Main girt C250×75×20×2.0, Q355B
Heavy girt C250×75×20×2.5 (back-to-back)
Canopy beam H300×250×6×12, Q355B
Window column C250×75×20×2.0
Door column C250×75×20×2.5 back-to-back

 

blog-821-264


System Components

 

Member Section Material
Wall girts QLT1-4 C250×75×20×2.0 / ×2.5 Q355B
Canopy beam YPL H300×250×6×12 Q355B
Window column CK C250×75×20×2.0 Q355B
Door column MK C250×75×20×2.5 back-to-back Q355B
Sag rods LT φ12 round bar Q235B
Diagonal rods XLT φ12 round bar Q235B
Spacer tube CG φ12 rod + φ32×2.5 tube Q235B
Knee braces YC L63×6 galvanized angle Q235B

How It Goes Together

The wall system works as one layered assembly:

  • Girts carry cladding: C250 girts span between wall columns, support wall panels
  • Sag rods prevent sag: φ12 rods through girt webs at mid-span
  • Spacer tubes at columns: φ32×2.5 tube at every column line
  • Knee braces stabilize: L63×6 angles brace girt bottom flange
  • Door/window columns: back-to-back C sections around openings

Advantages

  1. Complete package — girts, rods, tubes, braces all one system
  2. C250 efficient — C250×75×20 spans 8 m bays at 1.2 m spacing
  3. Back-to-back at openings — double C sections stiffen door and window openings
  4. Galvanized knee braces — L63×6 galvanized angles resist corrosion
  5. Q355B girts — lighter than Q235 for same span

Disadvantages / Limitations

  1. Thin 2.0 mm gauge — C250×75×2.0 dents during handling
  2. Many small parts — rods, tubes, angles add up over 48.5 m wall
  3. Galvanize needed — C purlins rust if not galvanized or painted
  4. Opening layout complex — door and window columns need careful coordination
  5. Cladding must match — girt spacing matches panel rib spacing

Typical Applications

  1. Industrial factory walls — supports metal wall panels
  2. Warehouse walls — long 48 m wall runs
  3. Door and window openings — reinforced C columns around openings
  4. Canopy edges — H300 canopy beam over entrance
  5. Cold storage walls — insulated panel wall support

blog-765-359


Installation Notes

  • C250 girts bolted to wall column tabs at 1,200 mm spacing
  • φ12 sag rods threaded through girt webs, tightened after alignment
  • φ32×2.5 spacer tubes placed at every column line
  • L63×6 galvanized knee braces bolted between girt and column
  • Back-to-back C columns at door and window openings

Steel wall girt system — C250×75×20 girts at 1.2 m spacing, H300 canopy beam, φ12 sag rods with φ32×2.5 spacer tubes, L63×6 galvanized knee braces, Q355B girts + Q235B bracing, 48.5 m long factory wall.

​​​​​​​**WhatsApp**: +86‑13889862778, +86‑18242444407
**Email**: eddie@zdsteels.com, wells@zdsteels.com

Previous article: Tapered H Beams: Why 700mm at Midspan, 400mm at Ends Saves Steel

YOU MAY LIKE